2 NHTSA safety recall campaigns were
found for the 1981 Dodge B100.
NHTSA Recall 83V103000
Component:
STRUCTURE:BODY:BUMPERS
Recall date:
1983-09-27
Defect Summary
VEHICLES MAY NOT MEET THE REQUIREMENTS OF FEDERAL MOTOR VEHICLE SAFETY STANDARD NO. 301, "FUEL SYSTEM INTEGRITY". IN AN IMPACT TEST FROM THE REAR, THE BUMPER SUPPORT STRUCTURE DEFORMED ENOUGH TO ALLOW CONTACT OF A SUPPORT BRACKET WITH THE FUEL TANK.
Safety Risk
Remedy
ALL RECALLED VEHICLES WILL RECEIVE FRAME REINFORCEMENTS PLUS TWO LOAD-BEARING RUB STRIPS AND PROTECTIVE IMPACT SHIELDING. ADDITIONALLY, A CORNER OF THE BUMPER BRACKET WILL BE REMOVED.
NHTSA Recall 81V019000
Component:
FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY
Recall date:
1981-01-09
Defect Summary
CERTAIN VEHICLES EQUIPPED WITH OPTIONAL STEP TYPE REAR BUMPER AND A 22-GALLON STEEL FUEL TANK MAY NOT COMPLY WITH REAR IMPACT TEST REQUIREMENTS OF FEDERAL MOTOR VEHICLE SAFETY STANDARD NO. 301, "FUEL SYSTEM INTEGRITY". IF THE VEHICLE IS INVOLVED IN A COLLISION, FUEL SPILLAGE COULD OCCUR.
Safety Risk
Remedy
THE 22-GALLON STEEL FUEL TANK AND ASSOCIATED PLUMBING AND HARDWARE COMPONENTS WILL BE REPLACED WITH A 36-GALLON PLASTIC FUEL TANK, INCLUDING PLUMBING AND HARDWARE.